Can't Find What You Need? Call Us: 0161 747 1551/1661
Signed overnight deliveries, ordered before 3pm [UK Mainland]

Kane Km458 no wireless chip Unit only

NOW SEE 458S FOR PRICING DUE 1ST WEEK JULY PRE-ORDER*

 

Unit c/w probe,charger and probe NO BAG Only box

  • Structured commission test
  • Rotary switch for ease of use
  • Data hold
  • Logs & prints reports with optional infra-red printer
    • Combustion
    • Pressure
    • Let-by & Tightness
    • Temperature
    • CO build up
    • Commission test
  • 6 year warranty if serviced annually by Kane
£475.00 inc. VAT
Item Code: KM458 No wireless chip
Expected Delivery: 2/3Days
Need Help? 0161 747 1551/1661 or Contact Us

NOW SEE 458S FOR PRICING DUE 1ST WEEK JULY PRE-ORDER*

 

Unit c/w probe,charger and probe NO BAG Only box

  • Structured commission test
  • Rotary switch for ease of use
  • Data hold
  • Logs & prints reports with optional infra-red printer
    • Combustion
    • Pressure
    • Let-by & Tightness
    • Temperature
    • CO build up
    • Commission test
  • 6 year warranty if serviced annually by Kane
Flue Gas Measurement Range Resolution Accuracy
Oxygen*2 0-21% 0.1% ±0.3%
Carbon Monoxide*1 0-20ppm
21-2,000ppm
Above 2000ppm Purge pump operates
1ppm ±3ppm
±5% reading
unspecified
Carbon dioxide*1 0-20% 0.1% ±0.3% volume
Efficiency (Net or Gross)*2 0-99.9% 0.1% ±1.0% reading
Efficiency High (C)*2 0-119.9% 0.1% ±1.0% reading
Excess Air*2 0-250% 0.1% ±0.2% reading
CO/CO2 ratio*2 0-0.999 0.0001% ±5% reading

*1 Using dry gases at STP
*2 Calculated

Pressure (differential) Range Resolution Accuracy
Nominal range ±80mbar
Maximum over range without damage to sensor is ±400mbar
±0.2mbar
±1mbar
±80mbar
Maximum
0.001mbar
<25mbar
±0.005mbar
±0.03mbar
±3% of reading
   
Pre-programmed Fuels Natural gas Propane, Butane, LPG, Light Oils (28/35 sec), Wood Pellets, Town Gas, Coke Gas, Bio Oil, Bio Gas
User programmed Fuels 5 user defined fuels
   
Storage Capacity 60 Combustion tests
20 Pressure & Temperature tests
20 Tightness tests
20 Temperature tests
20 Room CO tests
20 Room CO tests
20 Commissioning tests

Carbon Dioxide resolution is 0.01% below 1% measured value.

   
Ambient Operating Range 0°C to ±45°C 10% to 90% RH non-condensing
Battery Type / Life 4AA cells
>8 hours using Alkaline AA cells
Chargers (optional) 100-240v charger, for NiMH batteries only
12v in vehicle charger, for NiMH batteries only
Dimensions  
Weight 0.8kg handset with protective rubber cover
Handset 200 x 45 x 90mm
Probe 300mm long including handle
6mm diameter x 240mm long stainless steel shaft with 2m long neoprene hose. Type K thermocouple
Temp Measurement Range Resolution Accuracy
Flue Temperature 0-600°C 0.1°C ±2.0°C
±0.3% reading
Inlet Temperature
(Internal sensor)
0-50°C 0.1°C ±1.0°C
±0.3% reading
Inlet Temperature
(External sensor)
0-600°C 0.1°C ±2.0°C
±0.3% reading